Calculator
Example data table
| Scenario | Users | Flow/User (CFM) | Required Flow (CFM) | Air/Shift (SCF) | Project Days |
|---|---|---|---|---|---|
| Coating crew, full-face | 6 | 8 | ~59 | ~22,600 | 20 |
| Blasting hood team | 8 | 12 | ~120 | ~46,100 | 30 |
| Confined work, half-mask | 4 | 6 | ~30 | ~11,500 | 10 |
Formula used
Multiply by shifts/day and project days for totals.
Effective PSI includes a simple hose allowance.
How to use
- Count simultaneous airline respirator users.
- Select respirator type or enter custom flow.
- Enter shift schedule, utilization, and margins.
- Set hose length, pressure, and site altitude.
- Click Calculate, then export CSV or PDF.
Workforce demand drivers
Airline respirator demand starts with simultaneous users and each unit’s minimum airflow. Planning points are 6 CFM for half-mask, 8 CFM for full-face, and 12 CFM for hood or helmet units. Six full-face users create 48 CFM base demand. This calculator reports peak required flow for sizing and also estimates average shift flow using utilization for volume planning. Use the shift totals to compare rental packages and to plan fuel or electrical supply, and reduce unexpected mid-shift stoppages.
Margins that protect production
Jobsites add losses from quick-connects, drains, minor leaks, and purges. A loss allowance of 5–10% is common, and a contingency margin of 10–20% covers change orders or added staff. The diversity factor reflects how often everyone draws maximum flow together. Use 100% for worst-case, or 80–90% when tasks are staggered and patterns are proven. If you change crews daily, keep diversity higher until trends are stable.
Pressure, hose length, and altitude
Flow must arrive at stable pressure. Higher setpoints raise compressor horsepower, while long hose runs add pressure drop that must be covered at the source. The tool applies a simple hose allowance beyond 50 ft to reduce nuisance low-pressure events. Altitude also matters: lower density at elevation means more volumetric flow for equivalent breathing mass flow, so required CFM increases. When working above 5,000 ft, sizing errors become noticeable quickly.
Volume planning for shifts and projects
Once peak flow is set, consumption totals follow from time. Average CFM times minutes per shift yields standard cubic feet (SCF) per shift. Multiply by shifts per day and project days for total air volume. For example, 47 CFM average over eight hours uses about 22,600 SCF. These totals help plan rentals, power, receiver storage, and service intervals for dryers, filters, and monitor calibration.
Quality controls and documentation
Breathing air programs should include filtration, moisture control, CO monitoring, and documented inspections. Record checks by shift and verify the compressor package can deliver required CFM at effective pressure. Add receiver capacity if frequent connections cause short surges. Export the report to brief supervisors, align vendor curves, and standardize setup across crews.
FAQs
1) What is the difference between required CFM and average CFM?
Required CFM sizes the system for peak simultaneous demand. Average CFM applies utilization to estimate typical shift consumption and total project volume for planning power, fuel, and service intervals.
2) How should I choose a diversity factor?
Use 100% when all users may draw full airflow together. Use 70–90% when tasks are staggered and you have reliable work patterns, supervision, and historical performance data.
3) Why does altitude increase the airflow requirement?
Higher elevation reduces air density. To deliver the same breathing mass flow, the compressor must move a larger volume, so required CFM increases as altitude rises.
4) Can I use this for tool air and breathing air combined?
You can, but add tool demand separately because tools can spike flow. Increase contingency, confirm receiver capacity, and verify compressor controls for stable pressure under mixed loads.
5) What buffer storage setting should I use?
Two to five minutes often covers start-ups and brief surges. For long hose runs or frequent connections, increase buffer minutes and verify receiver size and pressure ratings.
6) Is the horsepower estimate exact?
No. It is a planning estimate that varies by compressor type and efficiency. Confirm final selection using manufacturer curves at your required CFM and effective pressure.
Safety and planning notes
- Use manufacturer flow requirements for each respirator model.
- Keep breathing air quality controls documented and maintained.
- Plan for filters, dryers, CO monitoring, and inspection routines.
- Validate compressor selection with vendor performance curves.