Surface Condensation Risk Calculator

Spot dampness before it stains interior finishes. Enter humidity, temperatures, and U-value for quick insights. See risk level, safety margin, and recommended targets instantly.

Calculator Inputs
Enter indoor conditions and surface information.
Use measured surface temperature, or estimate from U-value.
White theme • Single page
All temperature fields follow this setting.
°C
Typical range: 18–26.
%
Higher RH raises dew point and risk.
°C
Used for estimating surface temperature in U-value mode.
Choose measured surface temperature or estimate from assembly U-value.
°C
Measure with an IR thermometer for best accuracy.
W/m²·K
Lower U-value usually means warmer interior surfaces.
m²·K/W
Common default is 0.13 for still indoor air.
m²·K/W
Common default is 0.04 for outdoor exposure.
If unsure, leave unchecked for typical published U-values.
%
Common mold-risk screening value is 80%.
Reset

Example Data Table

These examples show how indoor humidity and surface temperature change risk.
Scenario Indoor (°C) Indoor RH Surface (°C) Dew Point (°C) Expected Outcome
Comfortable winter room 21 40% 17 ~7 Low risk
Humid bedroom, cool window 22 65% 13 ~15 Condensation likely
Bathroom after shower 24 80% 18 ~20 Very high risk
Improved glazing, same indoor RH 22 55% 18 ~13 Moderate to low

Formula Used

Note: Surface temperature can vary with air movement, thermal bridges, and radiant cooling. Use measured surface temperatures for critical assessments.

How to Use This Calculator

  1. Select temperature units, then enter indoor temperature and humidity.
  2. Enter outdoor temperature for U-value estimation mode.
  3. Choose a surface input method: measured surface temperature or U-value estimation.
  4. Click Calculate Risk to view results above the form.
  5. Download CSV or PDF to share moisture checks with your team.

Moisture patterns that trigger surface wetting

Surface condensation is a short-duration event with long-term consequences. When indoor air meets a cold surface, moisture can form as droplets, damp films, or recurring fogging on glazing. In occupied buildings, peak humidity often occurs in kitchens, bathrooms, laundry zones, and crowded rooms. Tracking these peaks helps explain complaints such as musty odor, stained paint, blistering finishes, and window puddling.

Dew point as a decision threshold

Dew point represents the temperature where air becomes saturated at the current moisture content. If the interior surface temperature falls at or below dew point, condensation becomes likely. The calculator also shows a safety margin, defined as surface temperature minus dew point. Margins near 0 indicate immediate risk, while small margins suggest that minor humidity spikes can cause wetting.

Interpreting surface relative humidity outputs

Surface relative humidity (RHs) is calculated from indoor vapor pressure and the saturation pressure at the surface temperature. Even without visible droplets, RHs can remain high near thermal bridges, corners, and window frames. Sustained RHs above a chosen threshold, often 80%, supports mold growth on dust layers and porous finishes. Use RHs to prioritize mitigation where condensation is intermittent.

Using U-value mode for early design screening

When surface temperature is not measured, U-value mode estimates the interior surface temperature from indoor and outdoor temperatures and resistances. Lower U-values usually keep interior surfaces warmer and increase the safety margin. This screening is useful for comparing assemblies, checking glazing upgrades, and evaluating retrofit concepts. For critical junctions, measure surface temperatures and review thermal bridging separately.

Field actions to reduce risk and document results

Reduce risk by lowering indoor humidity, increasing ventilation during moisture events, and improving surface temperatures through insulation continuity and draft control. Confirm improvements by re-running the calculator after changes and exporting the CSV or PDF for site records. Repeated entries across seasons reveal whether risk is a rare spike or a persistent condition requiring envelope or HVAC upgrades.

FAQs

1) What does the dew point tell me?

Dew point is the temperature where the current indoor moisture content reaches saturation. If a surface is at or below dew point, condensation can occur. A larger safety margin means a more robust buffer against wetting.

2) Should I use measured surface temperature or U-value mode?

Use measured surface temperature when you can access the surface and conditions are representative. Use U-value mode for quick screening during design or early audits. Thermal bridges can still dominate local risk.

3) Why can surface relative humidity exceed 100%?

RHs can exceed 100% when the estimated or measured surface temperature is below the dew point, meaning the air adjacent to the surface is supersaturated. In practice, that condition tends to produce liquid water on the surface.

4) What are Rsi and Rse values used for?

Rsi and Rse represent interior and exterior surface film resistances. They influence the estimated surface temperature in U-value mode. Defaults suit typical still-air conditions, but high air speed or wind exposure can change these resistances.

5) How do I lower the calculated risk quickly?

Reduce indoor humidity during peak events, run exhaust fans longer, avoid drying clothes indoors, and maintain stable heating in cold zones. Improve surface temperature by sealing drafts and upgrading insulation or glazing, especially at corners and frames.

6) When should I consult a specialist?

Consult a building professional when condensation is persistent, mold is visible, finishes are failing, or occupants report health concerns. A specialist can assess thermal bridges, ventilation balance, moisture sources, and compliance requirements using measurements and modeling.

Related Calculators

Mold Moisture Source CalculatorIndoor Humidity Risk CalculatorDew Point Mold CalculatorWall Cavity Moisture CalculatorBasement Dampness Index CalculatorVentilation Rate Mold CalculatorAir Exchange Need CalculatorBathroom Exhaust Sizing CalculatorKitchen Ventilation Need CalculatorCrawlspace Venting Calculator

Important Note: All the Calculators listed in this site are for educational purpose only and we do not guarentee the accuracy of results. Please do consult with other sources as well.