Track oxygen levels for hydroponics, ponds, and tanks. See saturation, deficit, and percent in seconds. Use results to time aeration and protect crops better.
| Temperature (°C) | Salinity (ppt) | Altitude (m) | Measured DO (mg/L) | Typical Interpretation |
|---|---|---|---|---|
| 20 | 0 | 0 | 7.5 | Healthy range for many reservoirs |
| 26 | 0 | 300 | 5.2 | Moderate; add aeration during warm periods |
| 18 | 2 | 0 | 6.8 | Good; slight salinity reduces saturation |
| 30 | 0 | 0 | 4.6 | Low; risk for roots and aquatic life |
This calculator estimates oxygen saturation in water using a practical freshwater polynomial, then applies simple corrections for salinity and altitude.
Dissolved oxygen supports root respiration and beneficial microbes, helping plants absorb nutrients efficiently. In ponds and aquaponics, it also protects fish and biofilters. Low oxygen often appears during warm afternoons, after heavy feeding, or when organic debris accumulates. Tracking saturation and deficit lets you correct problems before growth slows or odors develop. Consistent oxygen also reduces disease pressure in wet root zones.
Warm water holds less oxygen than cool water, so identical aeration can produce very different results across seasons. Altitude reduces air pressure, lowering the maximum oxygen the water can hold even when fully aerated. Salinity and dissolved minerals also reduce solubility. This calculator combines these effects to estimate a realistic saturation value for your conditions, not a generic sea‑level number. This improves comparisons between sites and tanks.
Saturation is the estimated ceiling for oxygen at your inputs. Percent saturation compares your measured reading to that ceiling. A deficit shows how many milligrams per liter are missing to reach equilibrium. In practical management, a rising deficit signals either insufficient aeration, excess biological demand, or increasing temperature. Use trends across days, not a single reading, to prioritize actions. Log readings at the same time daily for cleaner insights.
Increase water movement, break surface tension, and add fine‑bubble aeration to improve gas transfer. Clean filters, remove sludge, and avoid overfeeding in aquatic systems to reduce oxygen demand. In nutrient reservoirs, keep solution temperatures stable, shade tanks from sun, and prevent biofilm buildup on stones and lines. Small maintenance steps often outperform oversized equipment. Always verify improvements by re‑measuring after adjustments. during heat waves and peak demand.
Calibrate probes regularly and keep membranes, caps, and electrolyte in good condition. Allow readings to stabilize after moving the probe, and record temperature alongside oxygen. If numbers appear unusually high, check for cold inflow, microbubbles, or calibration drift. Store exports from this tool to build a baseline, then set alert thresholds that match your crop stage and stocking density. Weekly notes help.
Many reservoirs perform well around 6–8 mg/L. Warm solutions can run lower, but persistent values under 5 mg/L increase stress. Track percent saturation and trends, then adjust aeration, temperature, and cleanliness to stabilize oxygen supply.
Plants, algae, fish, and microbes consume oxygen continuously, but photosynthesis stops after sunset. If respiration exceeds aeration and mixing, DO declines overnight. Improve circulation, reduce nutrient loading, and consider timed aeration during the darkest hours.
Use saturation to estimate the maximum oxygen your water can hold. Enter measured DO when you have a meter reading; it unlocks percent saturation and deficit, which are more actionable for troubleshooting and verifying improvements after changes.
It uses a standard atmosphere pressure ratio that is reliable for typical elevations. Microclimate, weather, and indoor systems can vary slightly. For best results, log consistent readings and focus on relative changes rather than tiny single‑digit differences.
Extremely high values are uncommon in garden systems, but supersaturation can stress fish in closed setups. More often, high numbers indicate cold water or sensor issues. Confirm calibration, check for trapped bubbles, and compare with temperature and flow.
Add fine‑bubble aeration, increase circulation, and lower solution temperature a few degrees. Clean stones and lines to restore airflow. Reduce organic contamination and avoid stagnant corners. Re‑measure after 15–30 minutes to confirm improvement.