Wind Load Deck Railing Calculator

Size deck railing loads using wind speed and exposure. Export results for site notes. Build safer rails with consistent assumptions.

Calculator

Outputs adapt to your selected units.
mph at your site.
Used to estimate Kz.
ft to top of railing.
Use 1.0 for flat terrain.
Typical values: 0.85–0.95.
Common default: 0.85.
Solid panels higher; open rails lower.
Use 1.0 unless specified otherwise.
ft overall length.
ft above deck surface.
ft between posts.
Leave blank to skip the check.
Use your post/base connection capacity.
Included in exports.
Reset
Tip: If you only know local wind speed in km/h, divide by 3.6 to get m/s.

Formula used

This calculator applies a practical wind-pressure workflow and converts the result into railing forces.
Step Expression Meaning
1) Velocity pressure qz = 0.00256 · Kz · Kzt · Kd · V² Base wind pressure at height z.
2) Design pressure p = qz · G · Cf · I Applies gust, shape, and importance.
3) Line load w = p · H Load per length along the rail.
4) Total force F = w · L Total lateral force on the full run.
5) Post demand Fpost = w · S,   Mpost = Fpost · (H/2) Tributary post force and base moment.
Note: Kz is estimated from typical exposure values and interpolated by height. For permitting and final design, follow your local code and applicable standards.

How to use this calculator

  1. Pick units, then enter your site wind speed.
  2. Select exposure and the height to your railing top.
  3. Enter railing length, railing height, and post spacing.
  4. Adjust factors only when you have a reason.
  5. Optionally add post capacity values for quick checks.
  6. Press Calculate, then export results if needed.

Wind pressure grows with speed

Wind loading on a deck railing rises quickly because velocity pressure is proportional to wind speed squared. A change from 100 to 120 increases pressure by about 44%. This calculator converts that pressure into line load and post demand, so you can compare different wind speeds and see how much “extra” capacity you buy by choosing stronger posts.

Exposure and height shape the demand

Terrain exposure affects the height factor Kz. Sheltered suburban zones typically produce lower Kz values than open fields or coastal areas. Height matters too: a railing on an elevated deck “sees” stronger flow than one near grade. By entering the top-of-rail height, you get a more realistic pressure at your garden deck rather than a flat, one-size value.

Railing openness changes the coefficient

Force coefficient Cf represents how the railing presents area to wind. Solid panels generally attract higher loads than pickets, cable rails, or mesh. If you use a more open infill, use a lower Cf to reflect reduced drag and flow-through. Run two scenarios—solid and open—to bracket your design and document assumptions in the exported report.

Post spacing drives tributary forces

Even with the same pressure, wider post spacing increases the force each post must resist because each post supports a longer tributary segment. The calculator uses line load w = p × H and assigns tributary force as w × spacing. It then estimates base moment using a mid-height resultant, which is a practical check for brackets, bolts, blocking, and ledger connections.

Use results for planning, then verify

Exports make it easy to capture assumptions, notes, and outputs for site records. Treat “PASS” checks as a quick screen, not final approval. Confirm fastening, wood condition, corrosion resistance, and local code limits for guard systems. Pay special attention to corners and end posts, which can see higher demand depending on layout and shielding. When in doubt, consult a qualified professional for final sizing for every exposed deck.

FAQs

1) What wind speed should I enter?

Use the design wind speed required for your location and risk category. If you only know a regional map value, start there and adjust for local guidance or permitting requirements.

2) What does exposure category mean?

Exposure describes surrounding terrain roughness. Trees and buildings reduce wind near the surface, while open fields or coastal areas increase it. The choice changes Kz and therefore the final pressure.

3) How do I choose a force coefficient?

Solid panels tend to have higher coefficients than open pickets or cable rails. If you are unsure, use a conservative value and run a second scenario with a lower coefficient for comparison.

4) Why is post moment important?

Moment reflects how the lateral force creates rotation at the base connection. High moments often control fasteners, brackets, and blocking details. Strengthening the base can matter more than the post size.

5) Can I use metric inputs?

Yes. Select metric units, then enter wind speed in m/s and dimensions in meters. Outputs convert automatically to kPa, N/m, N, and N·m so you can compare scenarios consistently.

6) Are these results code compliant?

This tool provides planning estimates using common wind-pressure relationships. Code compliance depends on jurisdiction, load combinations, guard requirements, and connection details. Use it to inform decisions, then verify with local standards.

Example data table

Sample inputs and typical outputs for comparison. Values are illustrative.
Wind speed Exposure Railing (L × H) Spacing Design pressure Line load Post moment
115 mph C 12 ft × 3 ft 6 ft ~22 psf ~66 plf ~600 lb·ft
100 mph B 16 ft × 3.5 ft 8 ft ~14 psf ~49 plf ~690 lb·ft
130 mph D 10 ft × 3 ft 5 ft ~34 psf ~102 plf ~765 lb·ft