Plan compliant egress widths from occupant load fast. Select systems, groups, and exit quantities confidently. Get clear widths in inches and millimeters instantly here.
| Scenario | Occupant Load | Component | Sprinklered + Voice/Alarm | Factor (in/occ) | Required Total Width (in) | Notes |
|---|---|---|---|---|---|---|
| Office exit access doors | 300 | Other | No | 0.20 | 60 | Typical other-components sizing without reductions. |
| Sprinklered retail with voice/alarm | 400 | Other | Yes | 0.15 | 60 | Reduced factor can apply if not Group H or I-2. |
| Stair serving one level | 250 | Stair | No | 0.30 | 75 | Stairways often use a larger capacity factor. |
This calculator uses the common capacity method for sizing means of egress:
Important Note: All the Calculators listed in this site are for educational purpose only and we do not guarentee the accuracy of results. Please do consult with other sources as well.