Measure utilization of construction plants across any period. Include downtime, derates, and unit conversions easily. Download clean tables for site records and client reviews.
| Scenario | Basis | Rated | Period (h) | Downtime (h) | Derate | Actual Output | Net Capacity Factor |
|---|---|---|---|---|---|---|---|
| Week A | Energy | 500 kW | 168 | 16 | 0% | 52,000 kWh | 69.7% |
| Week B | Energy | 1.2 MW | 168 | 28 | 5% | 120 MWh | 63.7% |
| Shift Run | Production | 60 m³/h | 12 | 1 | 0% | 620 m³ | 93.9% |
| Monthly | Production | 95 t/h | 720 | 90 | 8% | 45,000 t | 86.2% |
| Seasonal | Production | 300 L/s | 2160 | 220 | 0% | 520,000 m³ | 86.0% |
Plant capacity factor links installed capability to real site output. For generators, batching plants, and dewatering systems, it shows how consistently equipment converts rated capacity into usable work. A 0.70 factor means 70% of the theoretical maximum was achieved during the measured period. Use weekly (168 h) snapshots for operations control and monthly summaries for client reporting.
Availability isolates time readiness: available hours equal period hours minus planned and unplanned downtime. If a plant runs 720 hours in a month with 90 hours downtime, availability is 87.5%. Capacity factor then adds the output dimension, so two plants with the same availability can show different utilization if one is under-loaded, throttled, or waiting on materials.
Gross capacity factor compares actual output against nameplate output across the full period. Net capacity factor tightens the denominator by applying available hours, derates, and optional losses, producing a decision-grade view for contracts and forecasting. In this calculator, Net CF is most useful when you track stoppages, partial-load operation, and temporary limits that reduce achievable output.
Derate captures known capacity reductions, such as altitude, temperature, wear, or flow restrictions. Losses represent downstream constraints, such as auxiliary loads, conversion losses, or off-spec production rejected by quality checks. Applying derate and losses to the available-hour maximum prevents overstating “possible” output and makes trend comparisons fair when conditions vary between periods.
Many construction plants show Net CF between 45% and 75%, depending on logistics and sequencing. Values above 75% indicate strong scheduling and stable demand, while values below 45% often signal frequent stops, long changeovers, or supply delays. Improve results by aligning material deliveries, reducing unplanned downtime, pre-planning maintenance windows, and matching plant size to the actual load profile. Track full-load hours to confirm whether constraints are time-based or capacity-based on site each month.
It quantifies how much of the plant’s theoretical output you actually delivered. Teams use it for benchmarking, forecasting, and explaining performance to clients, especially when comparing weeks, shifts, or subcontractor plant utilization.
Use energy for generators or equipment measured in kW and kWh. Use production for plants measured in rate and quantity, such as m³/h and m³, t/h and t, or units/h and units.
Pick a period that matches decisions. Weekly periods help operations and maintenance planning. Monthly periods support invoicing, audits, and trend reporting. Keep the same period length when you compare performance over time.
Gross uses full period hours and nameplate capacity. Net adjusts the maximum for downtime, derates, and losses, so it reflects what was realistically possible. Net is better for planning and accountability in variable conditions.
Yes. In energy mode, you can leave actual energy blank and enter average output instead. The calculator estimates energy using average output multiplied by available hours, which is useful when only power logs are available.
After a successful calculation, the tool stores the inputs and results for the current browser session. The download buttons export that saved snapshot as a structured CSV or a simple one-page PDF for filing and sharing.