Know when cartridges saturate before symptoms appear. Enter site data, see hours, shifts, and warnings. Download results, train crews, and schedule replacements confidently today.
| Scenario | Concentration | Breathing rate | Capacity | Exposure | Safety | Est. life (hours) |
|---|---|---|---|---|---|---|
| Vapor work inside enclosure | 35 ppm (MW 92.14) | 35 L/min | 120,000 mg | 100% | 2.0 | ~9.0 |
| Intermittent exposure during coating | 18 ppm (MW 78.11) | 30 L/min | 120,000 mg | 50% | 2.0 | ~25.0 |
| High humidity summer shift | 12 mg/m³ | 40 L/min | 120,000 mg | 100% | 3.0 | ~4.7 |
Air concentration and breathing rate determine how fast mass enters the cartridge. Concentration can be entered as mg/m³ or ppm. When ppm is used, molecular weight and temperature convert it to mg/m³ for a comparable loading basis. Breathing rate rises with heavy lifting, grinding, or confined work, so field programs often use task-specific rates rather than a single default.
Cartridge capacity is the total mass the sorbent can hold before contaminants pass through. Real service life is shorter because sorbent beds do not load evenly. Channeling, poor seals, and variable flow reduce usable capacity, so the utilization setting applies a practical fraction of rated capacity. Use vendor data when available, then validate with site observations and change-out records.
Moisture competes for adsorption sites and can reduce performance for many vapors. The calculator applies a conservative humidity factor that steps down as relative humidity increases. Temperature also affects adsorption and can accelerate desorption, so hotter conditions apply an additional reduction. If the manufacturer provides correction factors for your cartridge, replace these assumptions with those values.
The safety factor divides the theoretical life to create a planned replacement interval. Higher safety factors are appropriate when monitoring is limited, concentrations fluctuate, or consequences of breakthrough are severe. The tool also rounds the recommended interval down to 15‑minute blocks for practical scheduling. Always treat the recommended interval as a maximum and align it with your written respiratory protection program.
Outputs include estimated hours, equivalent shifts, and key calculation details such as effective capacity and mass loading rate. Use the results to schedule replacements within a shift, plan spare cartridge stock, and brief crews before starting tasks. Save CSV results for audit trails and training notes. For any unknown atmosphere or IDLH hazard, use supplied-air or escape-capable systems instead.
It estimates a planning service life based on contaminant loading versus effective sorbent capacity, then applies derating and a safety factor to recommend a conservative change interval.
It can document a time-based replacement plan, but particulate filters are typically changed by pressure drop, damage, or hygiene rules. Use your program criteria and follow the filter’s approval limitations.
Cartridges rarely load perfectly. Channeling, variable flow, seal leaks, and early breakthrough reduce usable capacity. Utilization lets you apply a realistic fraction of rated capacity for site conditions.
Base it on task intensity. Light inspection may be 20–25 L/min, while heavy labor can exceed 40 L/min. When unsure, choose a higher rate to avoid overestimating service life.
It uses an ideal-gas approximation at 1 atm. Accuracy depends on correct molecular weight and temperature. For mixed vapors or non-standard pressure, rely on measured mg/m³ or manufacturer guidance.
Treat it as a warning sign. Improve ventilation, reduce exposure time, select higher-capacity cartridges, or change the process. Consider upgrading respiratory protection and increase monitoring before work continues.