Surge Tank Sizing Calculator

Practical surge tank sizing for safer water systems. Enter flow, pipe data, and allowable surges. Get clear tank dimensions, volume, and oscillation period instantly.

Calculator inputs
Tip: use Tab to move through fields quickly.
Steady flow before the transient event.
Distance from reservoir/source to surge tank connection.
Use internal diameter for flow area.
Max rise above steady water level.
Max drop below steady water level.
Extra height above maximum surge level.
0 = full closure; 0.5 = half-flow; 1 = no change.
Custom area option uses your provided tank area.
Leave blank to auto-size the minimum area.
Output preferences
These only affect displayed results (calculations use SI).
Reset
Example data table
A typical set of inputs and the corresponding outputs (illustrative).
Case Q0 (m³/s) L (m) D (mm) Yup/Ydn (m) Q1/Q0 Fmin (m²) Tank Ø (m) T (s)
Baseline (defaults) 1.20 3000 1000 8 / 6 0.00 15.57 4.45 489
Partial change 1.20 3000 1000 8 / 6 0.50 3.89 2.23 245
Use your project constraints for allowable surges and freeboard.
Formula used
Preliminary sizing using rigid column theory for a simple surge tank.

This calculator applies the undamped (frictionless) rigid column model for a simple surge tank connected to a conduit of length L and area f. For an instantaneous discharge change, the maximum surge amplitude is approximated by:

Y = ΔV · √( (L · f) / (g · F) )

Where ΔV = |V0 − V1|, V0 = Q0 / f, V1 = (Q1/Q0) · V0, g = 9.81 m/s², and F is the surge tank cross-sectional area.

The tool sizes the minimum area to satisfy the tighter allowable amplitude (upsurge vs downsurge):

Fmin = (L · f) / ( g · (Ycrit / ΔV)² )

The undamped oscillation period is estimated as:

T = 2π · √( (L · F) / (g · f) )

Note: This is a fast, conservative screening method. Final design typically requires transient simulation, friction damping, and surge tank throttling checks.

How to use this calculator
  1. Enter the steady flow rate and conduit geometry (L and D).
  2. Set allowable upsurge and downsurge based on site limits.
  3. Choose a post-event flow fraction (0 for full closure).
  4. Click Calculate to view results above the form.
  5. Download CSV or PDF for your design package if needed.
Good practice checks
  • Ensure the minimum water level avoids air entry into the conduit.
  • Confirm the maximum water level stays below spill/overflow limits.
  • Review structural height, access, and constructability constraints.
  • For pumping stations, consider pump trip and check valve dynamics.

Related Calculators

Paver Sand Bedding Calculator (depth-based)Paver Edge Restraint Length & Cost CalculatorPaver Sealer Quantity & Cost CalculatorExcavation Hauling Loads Calculator (truck loads)Soil Disposal Fee CalculatorSite Leveling Cost CalculatorCompaction Passes Time & Cost CalculatorPlate Compactor Rental Cost CalculatorGravel Volume Calculator (yards/tons)Gravel Weight Calculator (by material type)