Plan ultra-low volume work using accurate sprayer output. Reduce chemical waste, downtime, and rework costs. Download CSV and PDF summaries for permanent site records.
Use the same units shown on each field. The tool provides raw and adjusted output values.
| Flow (ml/min) | Nozzles | Time (min) | Dosage (ml/m²) | Area (m²) | Loss (%) | Adj. Volume (L) | Rate (L/hr) |
|---|---|---|---|---|---|---|---|
| 250 | 2 | 15 | 20 | 200 | 10 | 6.750 | 27.00 |
| 180 | 1 | 25 | 15 | 350 | 8 | 4.140 | 9.94 |
| 320 | 3 | 12 | 25 | 150 | 12 | 10.137 | 50.69 |
ULV work succeeds when the applied volume matches the plan. Start with a catch test to confirm nozzle flow at the operating pressure, then use the calibration factor to align label flow with measured flow. When output is consistent, dosage targets become predictable across shifts and crews, reducing retreatment and chemical overuse.
Drift and evaporation can be significant around scaffolds, facades, and windy corridors. The loss factor lets you model real-world reduction from overspray, bounce, and air movement. For sheltered interior zones you may use a lower loss value; for exposed exterior work, plan higher losses and adjust scheduling to calmer windows.
The calculator converts your dosage (ml/m²) and area (m²) into required volume, then estimates the time needed based on total flow. This supports crew planning: you can confirm whether a tank load finishes a zone, or whether a refill point is needed. Coverage output also helps you compare alternative dosage targets safely.
Example set A: 250 ml/min per nozzle, 2 nozzles, 15 minutes, 20 ml/m² dosage, 200 m² area, 10% loss. Example set B: 180 ml/min, 1 nozzle, 25 minutes, 15 ml/m², 350 m², 8% loss. These values are typical for quick verification runs before full production spraying.
Exporting CSV and PDF creates a simple record of settings, adjusted output, and estimated treatment time. Keep these summaries with method statements, PPE controls, and product instructions. Consistent records support audits, improve handovers, and make it easier to justify changes when conditions or access constraints affect spraying performance.
It scales the calculated volume to match real flow. Use a positive value if measured output is higher than expected, or a negative value if measured output is lower.
It models drift, bounce, evaporation, and overspray. Using a realistic loss value improves the accuracy of adjusted volume, coverage, and time estimates.
Use the adjusted sprayed volume and output rate for field planning because they account for calibration and losses. Raw volume is best for quick equipment comparisons.
It multiplies adjusted solution volume by the concentration percentage. It is a simple proxy for chemical fraction, not a substitute for label-based mixing rules.
Start from the product instructions or the method statement for the task. Then run small-area trials to confirm coverage quality before scaling up.
Yes. Run the calculator for each spray segment or tank load. Save a CSV/PDF per segment to keep clear records of changes in time or settings.
No. It supports planning and documentation. Always follow product instructions, local regulations, ventilation requirements, and your site safety plan for ULV operations.
Important Note: All the Calculators listed in this site are for educational purpose only and we do not guarentee the accuracy of results. Please do consult with other sources as well.