Compressor Work Calculator

Model single or multistage compression with ease. See work, power, temperatures, density, and flow clearly. Export results and visualize operating trends with interactive charts.

Calculated Results

Final discharge temperature is last-stage discharge with perfect intercooling between equal-ratio stages.

Actual Specific Work
225.830 kJ/kg
Electrical Power
485.135 kW
Actual Discharge Temperature
137.409 °C
Pressure Ratio
7.000
Metric Value
Process ModelIsentropic
Stages2
IntercoolingPerfect
Pressure Ratio7.0000
Stage Pressure Ratio2.6458
Inlet Gas Density1.1686 kg/m³
Inlet Volumetric Flow1.7114 m³/s
Ideal Specific Work191.9557 kJ/kg
Actual Specific Work225.8303 kJ/kg
Ideal Gas Power383.9115 kW
Actual Gas Power451.6606 kW
Shaft Power460.8781 kW
Electrical Power485.1349 kW
Ideal Discharge Temperature120.5479 °C
Actual Discharge Temperature137.4093 °C
Estimated Heat Rise112.9151 kJ/kg
Annual Energy Use3,881,079.04 kWh
Annual Electricity Cost465,729.48

Calculator Inputs

Used only for the polytropic model.
Load Example Result Reset

Example Data Table

Case Gas Model P1 P2 T1 Stages ηc Actual Work Electrical Power
Reference Study Air Isentropic 1 bar 7 bar 25 °C 2 kg/s 2 with perfect intercooling 85% 225.83 kJ/kg 485.13 kW

This sample uses mechanical efficiency of 98%, motor efficiency of 95%, 8000 operating hours, and an electricity rate of 0.12 per kWh.

Formula Used

Pressure ratio: rp = P2 / P1

Stage pressure ratio: rs = rp1 / N

Inlet density: ρ1 = P1 / (ZRT1)

Inlet volumetric flow:1 = ṁ / ρ1

Isothermal specific work: w = ZRT1 ln(P2 / P1)

Isentropic discharge temperature: T2 = T1(P2 / P1)(k-1)/k

Isentropic specific work: w = (k / (k - 1)) ZRT1[(P2 / P1)(k-1)/k - 1]

Polytropic discharge temperature: T2 = T1(P2 / P1)(n-1)/n

Polytropic specific work: w = (n / (n - 1)) ZRT1[(P2 / P1)(n-1)/n - 1]

Actual specific work: wactual = wideal / ηc

Gas power: Pgas = ṁ × w

Shaft power: Pshaft = Pgas / ηmech

Electrical power: Pelec = Pshaft / ηmotor

Annual energy: E = Pelec,kW × operating hours

Annual cost: Cost = E × electricity rate

How to Use This Calculator

  1. Choose a gas preset or enter custom gas properties.
  2. Select isothermal, isentropic, or polytropic compression.
  3. Enter inlet pressure, outlet pressure, and inlet temperature.
  4. Provide mass flow rate, compressor efficiency, and stage count.
  5. Add optional mechanical and motor efficiencies for electrical demand.
  6. Enter yearly operating hours and your electricity rate.
  7. Click the calculate button to see work, power, temperature, and cost.
  8. Use the CSV or PDF buttons to export the result summary.

FAQs

1. What does compressor work mean?

Compressor work is the energy needed to raise a gas from inlet pressure to outlet pressure. It is often expressed as specific work in kJ/kg and then converted into power using mass flow rate.

2. Which model should I choose?

Use isothermal for ideal cooling, isentropic for adiabatic benchmark estimates, and polytropic when measured compressor behavior falls between those extremes. Polytropic often matches practical rotating compressor studies better.

3. Why is actual work higher than ideal work?

Real compressors have losses from friction, leakage, turbulence, heat transfer, and imperfect compression paths. Efficiency accounts for those losses, so actual work and required power are higher than ideal theoretical values.

4. What is the benefit of multistage compression?

Splitting compression into stages reduces stage pressure ratio and can lower required work when intercooling is used. It also helps control discharge temperature and improves equipment reliability at high pressure ratios.

5. Why does the calculator ask for gas constant and k?

Different gases respond differently during compression. The gas constant affects density and work, while the specific heat ratio affects temperature rise and isentropic calculations. Presets help fill typical values quickly.

6. What does the compressibility factor do?

The compressibility factor adjusts ideal-gas behavior for real-gas effects. A value near 1.0 means the gas behaves almost ideally. Deviations become more important at high pressures or unusual temperatures.

7. Can I estimate annual operating cost here?

Yes. Enter yearly operating hours and your electricity rate. The calculator estimates annual electrical energy use from calculated motor demand and multiplies it by the entered rate for a rough operating cost.

8. Is this suitable for final equipment design?

It is useful for screening, budgeting, and comparison studies. Final equipment design should also include vendor curves, suction conditions, gas composition, Reynolds effects, allowable temperature limits, and project safety margins.