Transformer Voltage Calculator

Compute step-up or step-down ratios with confidence today. Check EMF equation inputs for core limits. Download CSV or PDF to document every calculation clearly.

Calculator Inputs
Choose a mode, then provide values. Leave one field blank to solve.
Tip: Submit after switching to keep the correct fields visible.
What this mode solves
Ideal transformer ratio: if you provide three of Vp, Vs, Np, Ns, the calculator solves the missing one. If S is given, it also estimates primary and secondary current.
Reset

Formula Used

  • Turns ratio (ideal): Vp / Vs = Np / Ns
  • Power relation (approx.): Vp·Ip ≈ Vs·Is (ideal case)
  • Sinusoidal EMF: V ≈ 4.44 · f · N · Φm
  • Peak flux: Φm = Bmax · Ac (Ac in m²)
These relations are commonly used for first-pass transformer sizing and verification. Practical designs must include copper loss, core loss, leakage reactance, temperature rise, and regulation.

How to Use This Calculator

  1. Select a calculation mode: Turns Ratio or EMF Equation.
  2. Enter known values. Leave exactly one field blank to solve it.
  3. Press Calculate. The result appears above the form.
  4. Use Download CSV for spreadsheets, or Download PDF for printing.
Safety reminder: working with mains voltage can be hazardous. Always follow insulation, fusing, earthing, and enclosure best practices.

Example Data Table

Mode Inputs Computed Output
Turns Ratio Vp=230 V, Np=1200, Ns=63 Vs ≈ 12.075 V
Turns Ratio Vs=24 V, Np=1500, Ns=156 Vp ≈ 230.769 V
EMF Equation f=50 Hz, Bmax=1.2 T, Ac=25 cm², N=450 V ≈ 299.7 V
Example values are illustrative. Use measured core area and appropriate Bmax for your material.

Professional Notes and Reference Article

1. Why transformer voltage matters

Transformer secondary voltage sets the usable output for chargers, controls, and power supplies. A small ratio error can push regulation out of spec, raising ripple and heating. This calculator helps verify ratios early, before winding, insulation, and enclosure choices are locked.

2. Turns ratio fundamentals

For an ideal transformer, voltage scales with turns: Vp/Vs = Np/Ns. If you know any three values, solving the fourth prevents mistakes such as swapping primary and secondary turns. Example: 230 V with 1200 turns implies about 12.1 V at 63 turns.

3. Step-up and step-down behavior

A step-down design reduces voltage while increasing available current capacity. A step-up design does the opposite, raising voltage while reducing current. When Vs is higher than Vp, the output is step-up. When Vs is lower, the output is step-down.

4. Apparent power and current estimates

Apparent power S (VA) links voltage to current. If you enter S, the calculator estimates Ip ≈ S/Vp and Is ≈ S/Vs for an ideal case. For example, 60 VA at 12 V suggests about 5 A on the secondary, guiding wire gauge selection.

5. Core flux and volts-per-turn

The EMF equation mode uses V ≈ 4.44·f·N·Bmax·Ac for sinusoidal excitation. Typical silicon steel designs keep Bmax around 1.2–1.6 T to limit saturation. Volts-per-turn is a fast health check: higher values demand more flux and risk distortion.

6. Frequency considerations

Frequency directly affects voltage per turn. At 60 Hz, the same core and turns allow roughly 20% more voltage than at 50 Hz, assuming the same Bmax. If a transformer rated for 60 Hz is used at 50 Hz, it may need derating to avoid saturation.

7. Regulation and real-world losses

Practical outputs sag under load due to winding resistance and leakage reactance. Better regulation usually requires thicker conductors, tighter coupling, or different core geometry. Efficiency depends on copper loss (I²R) and core loss, which rises with flux density and frequency.

8. Practical verification checklist

Confirm your ratio target, then check volts-per-turn against your chosen Bmax and core area. Verify the VA rating supports expected load current with acceptable temperature rise. Finally, validate insulation, fusing, earthing, and clearances for the highest voltage present.

FAQs

1) Can I solve for a missing value in turns ratio mode?

Yes. Enter any three of Vp, Vs, Np, and Ns, and leave only one blank. The calculator solves the missing quantity using the ideal ratio relationship.

2) What does “apparent power (VA)” mean here?

VA is the product of RMS voltage and RMS current. It approximates power flow in an AC transformer and is commonly used for sizing windings and thermal limits.

3) Are the current results exact?

No. Current estimates assume an ideal transformer. Real units have copper loss and regulation, so measured currents and voltages under load can differ from calculated values.

4) Which mode should I use for design checks?

Use Turns Ratio mode to validate primary-to-secondary voltage relationships. Use EMF Equation mode to check volts-per-turn and flux limits when selecting turns, core area, and Bmax.

5) What Bmax value is reasonable?

It depends on the core material and temperature goals. Many laminated steel designs use roughly 1.2–1.6 T for conservative operation, while ferrites are typically lower.

6) Why does frequency change allowable voltage?

Higher frequency increases EMF for the same turns and flux, so you can achieve more voltage without increasing Bmax. Lower frequency pushes flux higher for the same voltage.

7) Can this calculator handle non-sinusoidal waveforms?

The EMF equation assumes a sinusoidal waveform. For square or distorted waveforms, effective voltage-per-turn differs, and you should use waveform-specific design methods or simulation.